ISO 8573-1:2010 [2:4:2]
Recommended Sampling Times:

Particle Class [2]Filter Sampling Time
(Particles & Oil Aerosol)
12 minutes.Min. air volume: 1200 L
Water Class [4]Detector Tube Sampling Time
(Water)
Note: Use the 20/a-P Detector Tube.
10 minutes.Min. air volume: 40 L
Oil Class [2]Charcoal Tube Sampling Time
(Oil Vapor)
10 minutes.Min. air volume: 40 L

ISO 8573-1:2010 Compressed Air Testing - Sampling Time Calculator

To calculate the recommended sampling times for your K8573NB or K8573NX AirCheck Kit™, select your desired Purity Classes below:


ISO 8573-1:2010 Compressed Air Contaminants and Purity Classes are listed below. If the specification you need is not shown, please Contact Us. We have many more air & gas specifications in our database. If you need a custom specification, Contact Us with your requirements.

ISO 8573-1:2010 Compressed Air Contaminants and Purity Classes

Class Particles Water Oil
By Particle Size
(maximum number of particles per m3) See Note 2
By Mass Vapor Pressure Dewpoint Liquid Liquid, Aerosol, & Vapor
See Note 1
0.10 – 0.5 microns 0.5 – 1.0 microns 1.0 – 5.0 microns mg/m3 °C °F g/m3 mg/m3
0 As specified by the equipment user or supplier and more stringent than class 1
1 ≤ 20,000 ≤ 400 ≤ 10 - ≤ -70 ≤ -94 - ≤ 0.01
2 ≤ 400,000 ≤ 6,000 ≤ 100 - ≤ -40 ≤ -40 - ≤ 0.1
3 - ≤ 90,000 ≤ 1,000 - ≤ -20 ≤ - 4 - ≤ 1
4 - - ≤ 10,000 - ≤ +3 ≤ +37 - ≤ 5
5 - - ≤ 100,000 - ≤ +7 ≤ +45 - -
6 - - - 0 – ≤ 5 ≤ +10 ≤ +50 - -
7 - - - 5 – ≤ 10 - - ≤ 0.5 -
8 - - - - - - ≤ 5 -
9 - - - - - - ≤ 10 -
X - - - > 10 - - > 10 > 5
  Microbiological Contaminants Other Gaseous Contaminants
  No purity classes are identified No purity classes are identified
Gases mentioned are: CO, CO2, SO2, NOX, Hydrocarbons in the range of C1 to C5

Note 1: ISO 8573 Oil includes aerosol, vapor in the range of C6+, and liquid oil. Liquid oil is typically sampled when wall flow is present, contamination is suspected, or results are greater than 5 mg/m3. Trace can provide a separate kit for liquid oil testing.

Note 2: For Particle Class 0, 1, & 2 (0.1 - 0.5 µ range only), a laser particle counter with a high-pressure diffuser is required. Rental of this equipment is available on a reservation basis. Contact us for details. To qualify for Particle Classes 0 through 5, there can be no particles greater than 5µ present.

In some cases, Trace uses alternative sampling techniques or analytical methods to those specified in ISO 8573, for details see Smith White Paper, 2012.

Air & Gas Specifications referenced above may be viewed and/or purchased from: ANSI - American National Standards Institute