SCBA Compressed Breathing Air Specifications

Trace Analytics, LLC specializes in the analysis of thousands of compressed breathing air samples each year.

Our scientifically designed compressed air testing kits make collection a simple task. Keep the small, portable kit, and return the lightweight sample via the shipping method of your choice.

Selected SCBA Compressed Breathing Air Specifications are shown below. If the specification you need is not shown, please Contact Us. We have many more air & gas specifications in our database. If you need a custom specification, Contact Us with your requirements.

SCBA Use - Selected Air Quality Specifications

Air Quality SpecificationTHCCOCH4CO2H2ODP, °FO2N2OILODOR
CGA Grade D (G-7.1-2011)N/A10N/A100067-5019.5-23.5N/A5None/Slight
CGA Grade L (G-7.1-2011) (SCBA)N/A10N/A100024-6519.5-23.5N/A5None/Slight
NFPA 1989-2013 (N)25 (T)5N/A100024-6519.5-23.575.0-81.02Not Pronounced
OSHA 1910.134 Respiratory Protection - 2004 Cylinder (Y)N/A10N/A100067-5019.5-23.5N/A5None/Slight
OSHA 1910.134 Respiratory Protection - 2004 SCBA (S)N/A10N/A100067-5019.5-23.5N/A5None/Slight
THC = Total Gaseous Hydrocarbons, ppmvCO2 = Carbon Dioxide, ppmvO2 = Oxygen, volume %HS = Halogenated Solvents, ppmv
CO = Carbon Monoxide, ppmvH2O = Water, ppmvN2 = Nitrogen, volume %Odor = Odor as supplied by customer
CH4 = Methane, ppmvDP = Dew Point, °F at 0 psigOil = Oil Mist & Particulate, mg/m3
Air & Gas Specifications referenced above may be viewed and/or purchased from: CGA - Compressed Gas AssociationNFPA - National Fire Protection AssociationOSHA - Occupational Health & Safety Administration